Special reverse osmosis IMT-NC9 R
IMT-NC9 R reverse osmosis system with ion exchanger — ultrapure water with conductivity up to 5 µS/cm, designed for dental practices, dental hygiene clinics and laboratories. It replaces buying or producing distilled water for dental units and autoclaves — just turn the tap.
- Guaranteed water conductivity up to 5 µS/cm, around 2 µS/cm in normal operation
- Three-stage filtration PPC + RO + R — pre-filtration, reverse osmosis membrane and special ion-exchange polishing
- Flow rate 2.23 l/min — ultrapure water for dental chairs and autoclaves all day long
- Fully automatic operation, filter life monitoring, automatic flushing
- Quick filter replacement without interrupting the water supply (bayonet lock)
- Cartridge life: PPC up to 12 months, RO up to 24 months, R up to 12 months
- Optional SMART faucet with TDS measurement, Wi-Fi and the E-Water app
- Proven in several dental practices · design by F.A. Porsche studio
| Category: | Reverse osmosis |
|---|---|
| Warranty: | 2 years |
| Místo instalace: | Pod dřez |
| Místo použití: | Pro firmy a gastro |
| Problém s vodou: | Tvrdá voda, vodní kámen, Železo, mangan, Koliformní bakterie, E. coli, viry, Dusičnany, dusitany, Těžké kovy, Hg, Co, Cu, As, Pb, Pesticidy, léky, drogy, hormony, Mikroplasty, Chlór |
| Typ filtru: | Reverzní osmóza |
Reverse osmosis for dental practices, dental hygiene clinics and laboratories — ultrapure water instead of distilled water
The special IMT-NC9 R reverse osmosis system produces ultrapure water with guaranteed conductivity up to 5 µS/cm for dental practices, dental hygiene clinics and laboratories. In normal operation, conductivity stays around 2 µS/cm. The water is suitable for dental chairs, dental hygiene chairs and autoclaves (steam sterilisers) of all classes. It removes viruses, bacteria, heavy metals, pesticides, pharmaceuticals, microplastics and nanoplastics. You will significantly cut the cost of buying or producing distilled water: just turn the tap and ultrapure water flows. The unit has been proven in practice in several dental practices and was designed by the F. A. Porsche design studio.
No more cleaning the distiller — more time for patients
A distiller produces water slowly and has to be laboriously descaled after every cycle. This daily routine takes up time that a nurse, dental assistant or dental hygienist could spend with patients. With the IMT-NC9 R, daily cleaning and monitoring of water production disappear completely. Ultrapure water is ready whenever you need it, and the only maintenance is replacing the filter cartridges once a year — the unit reminds you when it's time. The result: more time for patients, fewer worries and quiet, clean operation with no limescale.
Three filtration stages — PPC + RO + R
The IMT-NC9 R system works with three filter cartridges:
- PPC: water pre-treatment.
- RO: special reverse osmosis membrane with a filtration rating of 0.0001 μm.
- R: special ion-exchange cartridge for thorough polishing of the water to ultrapure quality.
The PPC and R cartridges last up to 12 months, the RO membrane up to 24 months. All materials used are certified for drinking water and the functional parts of the filter are made of stainless steel.
Fully automatic operation with display
The IMT-NC9 R is equipped with a 150 W pump and a clear integrated display. The display shows the unit status and filter life and alerts you when maintenance is needed. Automatic flushing keeps the membrane in good condition without any operator intervention. With a flow rate of 2.23 l/min, it supplies ultrapure water throughout the working day. Filter replacement takes 5 seconds thanks to the bayonet lock, without interrupting the water supply.
SMART faucet with Wi-Fi and the E-Water app (optional)
In the SMART faucet version (matte black only), the unit continuously measures TDS (total dissolved solids) and displays water quality in real time. The unit can be connected to a Wi-Fi network and controlled via the E-Water mobile app. The SMART faucet is used exclusively for dispensing filtered water. It is not a three-way faucet.
Calculate how quickly the IMT-NC9 R pays for itself
This interactive calculator for dental practices, dental hygiene clinics and laboratories compares the cost of the IMT-NC9 R with buying distilled water and running distillers. Enter your daily consumption and prices to see your annual savings and payback period.
Open the payback calculator →
| Technical specifications | |
|---|---|
| Water purity (conductivity) | guaranteed up to 5 µS/cm, typically around 2 µS/cm |
| Filtration rating | 0.0001 μm |
| Flow rate | 2.23 l/min |
| Motor power | 150 W |
| Power supply | 100–240 V, 50/60 Hz |
| Filter types | PPC + RO + R |
| PPC and R service life | up to 12 months |
| RO membrane service life | up to 24 months |
| Material of functional parts | stainless steel |
| PE tubing diameter | 1/4", 3/8" |
| Dimensions | 459 × 160 × 443 mm |
| Package / weight | 557 × 294 × 548 mm / 13 kg |
| Colour | silver |
| Certification | CE, SGS, RoHS |
| Package contents |
|---|
| 🟢 IMT-NC9 R filtration unit |
| 🟢 Power adapter |
| 🟢 T-valve 1/2" 3/8" |
| 🟢 Drain connection kit |
| 🟢 3/8" tubing (1.5 m) |
| 🟢 1/4" tubing (1.5 m) |
| 🟢 Installation manual |
⚠ WARNING: Water from the IMT-NC9 R is demineralised and is intended exclusively for technical use in dental practices, dental hygiene clinics and laboratories (dental units, autoclaves). It is not intended for drinking. The SMART faucet is supplied in matte black only and is used exclusively for dispensing filtered water. It is not a three-way faucet.
FREQUENTLY ASKED QUESTIONS
Everything you need to know about the IMT-NC9 R reverse osmosis system
What is the IMT-NC9 R and what is it used for?
The IMT-NC9 R is a special under-sink reverse osmosis system for producing ultrapure water with conductivity up to 5 µS/cm. It is designed for dental practices, dental hygiene clinics and laboratories, where it replaces buying or producing distilled water.
What water purity does the IMT-NC9 R guarantee?
We guarantee water conductivity up to 5 µS/cm. In normal operation, the value stays around 2 µS/cm. Ultrapure quality is ensured by the combination of a reverse osmosis membrane and the special R ion-exchange cartridge.
Which equipment can the IMT-NC9 R water be used in?
The ultrapure water is suitable for dental chairs, dental hygiene chairs, autoclaves (steam sterilisers) of all classes and laboratory use. It serves dental practices, dental hygiene clinics and laboratories wherever distilled water has been used so far.
What is the difference between the IMT-NC9 R and the IMT-NC9 nanofiltration system?
The IMT-NC9 nanofiltration system is designed for households. It removes contaminants but retains minerals and produces high-quality drinking water. The IMT-NC9 R uses a reverse osmosis membrane and an ion-exchange cartridge to produce demineralised ultrapure water for dental practices, dental hygiene clinics and laboratories. Water from the IMT-NC9 R is intended exclusively for technical use and must under no circumstances be used for drinking.
Is the IMT-NC9 R worth it compared with distilled water?
Yes. You no longer need to buy canisters of distilled water or run a distiller, which is slow and requires laborious daily descaling. You save not only money but also staff time that can be spent with patients. The only running cost is the regular replacement of filter cartridges. Calculate the exact savings for your practice with our payback calculator.
What is the difference between the version without a faucet and the SMART faucet version?
The version without a faucet (CZK 28,990) is the standard model with no tap. The version with the SMART faucet (CZK 29,990) includes a special matte black tap with a display showing TDS and filter life. It supports Wi-Fi and the E-Water app. The SMART faucet is used exclusively for dispensing filtered water and is not a three-way faucet.
How often are the filter cartridges in the IMT-NC9 R replaced?
The PPC and R cartridges last up to 12 months, the RO membrane up to 24 months. The unit monitors filter life itself and shows a replacement alert on the display.
How are the filters in the IMT-NC9 R replaced?
Filter replacement takes 5 seconds thanks to the bayonet lock, and no tools are needed. Procedure:
- Shut off the water supply to the unit.
- Open the filtered water tap to release the pressure.
- Replace the cartridge.
- Open the water supply again.
What if our water is very hard or highly mineralised?
The IMT-NC9 R handles very hard and highly mineralised water without any problems. The reverse osmosis membrane together with the R ion-exchange cartridge reliably removes calcium, magnesium and other dissolved salts, so ultrapure water with conductivity up to 5 µS/cm is guaranteed even from hard water. Unlike a distiller, there is also no limescale to remove. If you are unsure about your water quality, we will be happy to advise you free of charge based on a water analysis.
🦷 Proven in practice: The IMT-NC9 R has been in long-term operation in several dental practices, where it has replaced buying and producing distilled water for dental units and autoclaves. See how much you can save with our savings calculator.
Didn't find your answer? Ask us directly — we answer Mon–Thu 8 am–4 pm, Fri 8 am–2 pm (CET).
Product rating
Leave a rating
List of ratings
Discussion
Be the first who will post an article to this item!