Ultrafiltration Unit IMT-U7
H2O nanotec IMT-U7 whole-house ultrafiltration – clean water throughout the house without electricity. The unit is installed on the main water supply and its 0.01 µm membrane physically removes bacteria, viruses, sludge and microplastics. It is suitable for family houses, flats, offices and guesthouses supplied with well water or mains water.
Key benefits of H2O nanotec IMT-U7 ultrafiltration
- Physically removes bacteria including E. coli, viruses, sludge and algae
- Captures microplastics, while minerals stay in the water
- A more effective alternative to a UV lamp – works without electricity and without bulb replacement
- Filters all the water in the building – kitchen, bathroom and garden
The heart of the unit is a hydrophilic PAN (polyacrylonitrile) membrane with 0.01 µm pores in a brushed 304 stainless steel housing. It runs on mains water pressure alone and flushes captured impurities to the drain.
Technical highlights of IMT-U7 ultrafiltration
- 3 m³/h flow rate for the whole house
- 0.01 µm PAN membrane, life up to 36 months
- No electricity needed, operating pressure 0.1–0.4 MPa
- 1" connection, 304 stainless steel housing
| Category: | Ultrafiltration |
|---|---|
| Warranty: | 2 years |
| Weight: | 12.9 kg |
| Filter type: | Ultrafiltration |
| Installation location: | Whole house (main supply) |
| Place of use: | For households, For wells / cottages, For businesses and catering |
| Water problem: | Coliform bacteria, E. coli, viruses, Microplastics |
Why use whole-house ultrafiltration?
Both well water and mains water can contain bacteria, viruses, sludge or rust, and in recent years also microplastics. These impurities end up in your drinking water, shower and appliances.
The IMT-U7 ultrafiltration unit captures them on a membrane with 0.01 µm pores before the water is distributed around the house.
Unlike a UV lamp or chlorination, it does not merely inactivate microorganisms – it physically removes them from the water, including dead cells. Minerals such as calcium and magnesium remain in the water.
How does IMT-U7 ultrafiltration work?
Driven by mains pressure, water flows through the hollow fibres of the ultrafiltration membrane. Clean water passes through, impurities stay on the membrane surface and are carried to the drain during flushing.
Filtration includes:
- 0.01 µm PAN membrane – hydrophilic polyacrylonitrile resistant to biofouling, captures bacteria, viruses, sludge and microplastics.
- Membrane flushing – captured impurities are flushed to the drain, which extends membrane life. The IMT-P-W6 flushing valve does this automatically.
- Recommended pre-filter – an IMT-M5 pressure regulator with pre-filter or IMT-M8 upstream of the unit captures coarse impurities and significantly extends membrane life.
The IMT-U7 needs no electricity, chemicals or UV bulb replacement. It runs on household mains pressure of 0.1–0.4 MPa alone.
What does the IMT-U7 help remove from water?
A membrane with 0.01 µm pores reliably captures particles and microorganisms larger than its pores:
- bacteria including E. coli and coliform bacteria,
- viruses,
- sludge, rust, sediments and algae,
- microplastics.
Notice: Ultrafiltration does not remove dissolved substances – pesticides, pharmaceuticals, hormones, heavy metals, nitrates or water hardness – and may not reliably capture the smallest nanoplastic particles. For dissolved substances, nanofiltration at the drinking water tap is suitable; for hard water, a water softener.
Who is whole-house ultrafiltration suitable for?
The IMT-U7 is designed for buildings where you want clean water at every tap, in the shower and for your appliances.
IMT-U7 ultrafiltration is especially appreciated by:
- owners of houses and cottages with a well,
- households bothered by sludge and rust from the mains,
- family houses and flats with normal water consumption,
- offices and smaller guesthouses.
The effectiveness of water treatment always depends on the water's composition. For well water, we recommend having it analysed first – we will be happy to help you evaluate the results.
Why the IMT-U7 instead of a UV lamp?
A UV lamp inactivates microorganisms with radiation, but their bodies remain in the water. It needs electricity, regular bulb replacement and radiation intensity checks, and it does not capture sludge or microplastics.
IMT-U7 ultrafiltration physically removes bacteria and viruses, also captures mechanical impurities and works without electricity.
| IMT-U7 vs. UV lamp | ||
|---|---|---|
| IMT-U7 | UV lamp | |
| Bacteria and viruses | physically removes | inactivates, they remain in the water |
| Sludge, rust, microplastics | captures | does not capture |
| Electricity | not needed | required |
| Regular maintenance | membrane flushing | bulb replacement, radiation checks |
| Minerals in water | preserved | preserved |
Installing IMT-U7 ultrafiltration
The unit is installed on the main water supply where it enters the building (point of entry), so it filters all the water. It can be placed horizontally or mounted on a wall using the supplied brackets.
Installation steps:
- Close the main water supply.
- We recommend fitting an IMT-M5 or IMT-M8 pressure regulator with pre-filter upstream of the unit.
- Connect the IMT-U7 to the supply (1" connection, reducers included) according to the installation manual and drilling template. We also recommend fitting a bypass so that water can be routed around the filter during maintenance.
- Connect the flushing outlet to the drain.
- Slowly open the water, check for leaks and carry out the first flush.
We recommend having a plumber install the unit on the main supply – see also DIY installation.
Will the IMT-U7 affect water pressure or flow?
The 3 m³/h flow rate covers the normal consumption of a family house or flat, including simultaneous use at several points. Pressure loss with a new membrane is small. As the membrane gradually clogs, the flow may drop – regular flushing restores it.
For larger buildings with higher consumption, such as guesthouses, hotels or businesses, we recommend IMT-U8 ultrafiltration with a higher flow rate, or several units connected in parallel.
How to care for the IMT-U7 and when to replace the membrane?
The PAN membrane lasts up to 36 months, depending on the quality of the incoming water. Regular flushing removes captured impurities and extends its life.
Consider replacing the membrane if:
- approximately 36 months of operation have passed,
- the flow has dropped significantly even after flushing,
- the quality of the filtered water has deteriorated.
You can replace the membrane yourself. An IMT-M5 or IMT-M8 pressure regulator with pre-filter significantly extends its life.
Clean water throughout the house without electricity
IMT-U7 ultrafiltration protects the water throughout the building – from the kitchen to the bathroom. It physically removes microorganisms and mechanical impurities and leaves minerals in the water.
Thanks to operation without electricity and long membrane life, it is an economical and reliable solution for houses and wells alike.
Main advantages of IMT-U7 ultrafiltration
- 0.01 µm membrane,
- removes bacteria and viruses,
- captures sludge, rust and algae,
- captures microplastics,
- preserves minerals,
- 3 m³/h flow rate,
- no electricity needed,
- membrane life up to 36 months,
- 304 stainless steel housing,
- UV lamp replacement.
| Technical specifications | |
|---|---|
| Model | IMT-U7 |
| Product type | whole-house ultrafiltration unit |
| Membrane | PAN (polyacrylonitrile), 0.01 µm |
| Flow rate | 3 m³/h |
| Connection | 1" (reducers included) |
| Inlet pressure | 0.1–0.4 MPa |
| Operating temperature | 5–38 °C |
| Membrane life | up to 36 months |
| Dimensions | 549 × 277 × 262 mm |
| Housing material | 304 stainless steel |
| Electricity | not needed |
| Certification | CE, RoHS |
| Package contents |
|---|
| 🟢 IMT-U7 filtration unit |
| 🟢 1" and 3/4" nipples – 3 pcs |
| 🟢 Installation kit |
| 🟢 Drilling template |
| 🟢 Installation manual |
⚠ NOTE: A drain for membrane flushing is required at the installation site.
FREQUENTLY ASKED QUESTIONS
Everything you need to know about IMT-U7 ultrafiltration
What is the IMT-U7 and what is it for?
The IMT-U7 is a whole-house ultrafiltration unit with a membrane with 0.01 µm pores. It is installed on the main water supply and filters all the water in the building. It removes bacteria, viruses, algae, sludge, sediments and microplastics and keeps minerals such as calcium and magnesium in the water.
Will the IMT-U7 replace a UV lamp?
Yes. A UV lamp only inactivates bacteria and viruses, and their bodies remain in the water. IMT-U7 ultrafiltration physically captures microorganisms and removes them from the water, including dead cells. It also works without electricity and without replacing UV bulbs.
Will the IMT-U7 remove E. coli and coliform bacteria from well water?
Yes. The membrane has 0.01 µm pores, while E. coli bacteria measure 0.5–5 µm – so they are 50 to 500 times larger than the membrane pore. The bacteria are physically captured and removed from the water. Read more in the article How to Remove Coliform Bacteria and E. coli from a Well.
How does IMT-U7 ultrafiltration differ from IMT-NC9 nanofiltration?
The IMT-U7 (0.01 µm) removes bacteria, viruses, sludge and microplastics, but not dissolved substances such as pesticides, pharmaceuticals, hormones or heavy metals. IMT-NC9 or IMT-RS8 NANO membrane nanofiltration (0.001 µm) removes them, but it is an under-sink solution for a single drinking water tap. For maximum protection, the two systems can be combined.
Is the IMT-U7 suitable for well water?
Yes. The IMT-U7 reliably removes bacteria, viruses, algae, sludge and sediments typical of well water. If the water also contains pesticides, nitrates or heavy metals, we recommend adding nanofiltration at the drinking water tap. We will be happy to advise you based on a water analysis.
How long does the IMT-U7 membrane last and how is it replaced?
The PAN membrane lasts up to 36 months, depending on the quality of the incoming water. An IMT-M5 or IMT-M8 pressure regulator with pre-filter upstream of the unit significantly extends its life. You can replace the membrane yourself.
Does the IMT-U7 need electricity or a booster pump?
No. The IMT-U7 runs on household mains pressure of 0.1–0.4 MPa alone and needs no electricity or booster pump. This makes it inexpensive to run and silent.
What is the flow rate of the IMT-U7 and what size of house is it for?
The flow rate is 3 m³/h, which covers the needs of a typical family house or flat. For guesthouses, hotels or businesses with higher consumption, we recommend the IMT-U8 model with a higher flow rate, or several units connected in parallel.
Do I need a drain for the IMT-U7?
Yes. Captured impurities are flushed from the membrane to the drain, so a drain must be available at the installation site.
🔬 How ultrafiltration works: The effectiveness of ultrafiltration in removing E. coli and coliform bacteria from well water has been described by RNDr. Jiří Polman CSc., Managing Director of H2O nanotec, with reference to scientific literature (LeChevallier et al., Applied and Environmental Microbiology, 1988). Read more on the H2O nanotec blog: How to Remove Coliform Bacteria and E. coli from a Well.
Didn't find your answer? Ask us directly — we reply Mon–Thu 8 am–4 pm, Fri 8 am–2 pm (CET).
Product rating
Leave a rating
List of ratings
Discussion
Be the first who will post an article to this item!